Part Number: W92-X112-1 | Manufacturer: Tyco Electronics Corp | NSN: 5925-01-520-8619 |
Item Name : Circuit Breaker | CAGE Code: 77342 | FSC CODE: 5925 Circuit Breakers |
Alternate P/N : W92X1121 |
We are pleased to inform you that Part Number W92-X112-1 Circuit Breaker. of manufacturer Tyco Electronics Corp associated with NSN 5925015208619 is in stock. You can request a quote for this part W92-X112-1 by filling out the form provided below. Once the request is received, one of our representatives will get back to you within 15 minutes.
Download the ASAP Semiconductor app on Google Play or the Apple App Store
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-520-8619 Item Description: Circuit Breaker | 5925 | 015208619 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
W92-X112-1 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AEBY | Distance Between Centerlines Of Mounting Facilities Parallel To Body Length | 2.062 INCHES NOMINAL |
BBRG | Storage Type | GENERAL PURPOSE WAREHOUSE |
CQXF | Inclosure Protection Type For Which Designed | DUSTPROOF |
CPLM | Maximum Continuous Load Current Rating Per Pole | 1.0 AMPERES AC ALL LOCATIONS |
AKPX | Pole Quantity | 2 |
BBRJ | Special Handling Feature | MAGNETIC |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 1000.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
AFJN | Fragility Factor | MODERATELY RUGGED |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRL | Trip Release Characteristic | TIME DELAY ALL LOCATIONS |
CPRJ | Trip Release Method | MAGNETIC-HYDRAULIC ALL LOCATIONS |
AJEC | Boss Height | 0.140 INCHES NOMINAL |
CPRQ | Reset Method | MANUAL |
AEHA | Distance Between Centerlines Of Mounting Facilities Parallel To Body Width | 0.750 INCHES NOMINAL |
ADAT | Body Width | 1.500 INCHES NOMINAL |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRW | Actuator Function | TRIP-RESET |
CPRY | External Actuator Linkage Arrangement | ONE AND TWO LINKED |
CPRT | Manual Actuator Type And Quantity | 2 TOGGLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
AXHR | Mounting Facility Type And Quantity | 4 THREADED HOLE |
CQJX | Nominal Thread Size | 0.138 INCHES |
ADTV | Case Material | PLASTIC |
AJWX | Mounting Surface To Terminal End Distance | 2.471 INCHES NOMINAL |
ADAQ | Body Length | 2.500 INCHES NOMINAL |
AEBP | Center To Center Distance Between Terminals Parallel To Length | 1.938 INCHES NOMINAL |
THSD | Thread Series Designator | UNC |
AAQL | Body Style | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
TTQY | Terminal Type And Quantity | 4 THREADED STUD |
AEBQ | Center To Center Distance Between Terminals Parallel To Width | 0.750 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 250.0 AC ALL LOCATIONS |
APNQ | Arc Quenching Method | MAGNETIC BLOWOUT |
CQWN | Trip Delay Time In Seconds Per Rated Continuous Current | 2.000 MINIMUM AT 200 PCT ALL LOCATIONS AND 20.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
CPRX | Actuator Position Designation | AT EACH POLE |
CMLP | Thread Quantity Per Inch | 32 |