Part Number: NX102U | Manufacturer: Rockwell Automation Ltd | NSN: 5905-00-884-1455 |
Item Name : Resistor Variable N | CAGE Code: 01121 | FSC CODE: 5905 Resistors |
We are pleased to inform you that Part Number NX102U Resistor Variable N. of manufacturer Rockwell Automation Ltd associated with NSN 5905008841455 is in stock. You can request a quote for this part NX102U by filling out the form provided below. Once the request is received, one of our representatives will get back to you within 15 minutes.
Download the ASAP Semiconductor app on Google Play or the Apple App Store
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5905-00-884-1455 Item Description: Resistorvariablenonwire Wound | 5905 | 008841455 | N | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Nx102u | 1 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AAPN | SECTION QUANTITY | 1 |
AAQL | BODY STYLE | RECTANGULAR WMOUNTING HOLESSLOTS |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHP | OVERALL LENGTH | 1 312 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 0 953 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 0 953 INCHES NOMINAL |
ABWV | SHAFT DIAMETER | 0 109 INCHES MINIMUM AND 0 141 INCHES MAXIMUM |
ABXF | SHAFT LENGTH | 0 046 INCHES MINIMUM AND 0 078 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1 234 INCHES MINIMUM AND 1 266 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0 234 INCHES MINIMUM AND 0 266 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 0 343 INCHES MINIMUM AND 0 375 INCHES MAXIMUM |
AEDX | SHAFT STYLE | ROUND CROSS SLOTTED |
AEFD | ACTUATOR TYPE | SINGLE SHAFT |
AEHT | CENTER TO CENTER DISTANCE BETWEEN TERMINALS | 0 700 INCHES NOMINAL |
APXH | TERMINAL LOCATION | LOWER ADJACENT SIDE SINGLE ROW |
AXGY | MOUNTING METHOD | TERMINAL |
AYQR | CENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS | 0 100 INCHES NOMINAL |
CBBL | FEATURES PROVIDED | NONMETALLIC SHAFT |
CQCC | ELECTRICAL RESISTANCE PER SECTION | 1 000 KILOHMS SINGLE SECTION |
CQCM | CENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL | 0 290 INCHES MINIMUM AND 0 310 INCHES MAXIMUM |
CQGN | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER | 100 0 SINGLE SECTION |
CRGD | POWER DISSIPATION RATING PER SECTION IN WATTS | 0 333 FREE AIR SINGLE SECTION |
CRSS | RESISTANCE TOLERANCE PER SECTION IN PERCENT | -10 0 TO 10 0 SINGLE SECTION |
CSDH | AMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER | 50 0 SINGLE SECTION |
TTQY | TERMINAL TYPE AND QUANTITY | 3 CONNECTOR RECEPTACLE |
If you have more than one item, you can also send us your part number list (Spreadsheet) by uploading your list here.
Upload
At Complete Sourcing Solutions, You Can Get Quote for Your Required Part Number Within 15 Minutes. Just Fill Out the Instant RFQ Form.
Request for Quote