Part Number: 727937-2 | Manufacturer: General Dynamics Ots Inc | NSN: 5950-01-324-4310 |
Item Name : Transformer Power | CAGE Code: 21562 | FSC CODE: 5950 Coils and Transformers |
Alternate P/N : 7279372 |
We are pleased to inform you that Part Number 727937-2 Transformer Power. of manufacturer General Dynamics Ots Inc associated with NSN 5950013244310 is in stock. You can request a quote for this part 727937-2 by filling out the form provided below. Once the request is received, one of our representatives will get back to you within 15 minutes.
Download the ASAP Semiconductor app on Google Play or the Apple App Store
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-324-4310 Item Description: Transformerpower | 5950 | 013244310 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
11-00034-001 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ACZB | FREQUENCY RATING | 100 0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1 165 INCHES NOMINAL |
AXGY | MOUNTING METHOD | TAB SINGLE GROUP |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1 073 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKW | OVERALL HEIGHT | 1 476 INCHES NOMINAL |
ADAT | BODY WIDTH | 1 154 INCHES NOMINAL |
CRBZ | WINDING OPERATING CURRENT | 1 0 AMPERES DC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
TTQY | TERMINAL TYPE AND QUANTITY | 12 PIN |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0 354 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 50 0 WATTS SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 120 0 DEG CELSIUS |
AFHM | MOUNTING TAB WIDTH | 0 012 INCHES NOMINAL |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CWJS | WINDING OPERATING VOLTAGE | 140 00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
TEST | TEST DATA DOCUMENT | 16340-11-00034 DRAWING THIS IS THE BASIC GOVERNING DRAWING SUCH AS A CONTRACTOR DRAWING ORIGINAL EQUIPMENT MANUFACTURER DRAWING ETC EXCLUDES ANY SPECIFICATION STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
At Complete Sourcing Solutions, You Can Get Quote for Your Required Part Number Within 15 Minutes. Just Fill Out the Instant RFQ Form.
Request for Quote