Part Number: SM3-0-25-50VDC2 | Manufacturer: Eaton Corp | NSN: 5925-00-615-8376 |
Item Name : Circuit Breaker | CAGE Code: 74193 | FSC CODE: 5925 Circuit Breakers |
Alternate P/N : SM302550VDC2 |
We are pleased to inform you that Part Number SM3-0-25-50VDC2 Circuit Breaker. of manufacturer Eaton Corp associated with NSN 5925006158376 is in stock. You can request a quote for this part SM3-0-25-50VDC2 by filling out the form provided below. Once the request is received, one of our representatives will get back to you within 15 minutes.
Download the ASAP Semiconductor app on Google Play or the Apple App Store
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-00-615-8376 Item Description: Circuit Breaker | 5925 | 006158376 | P | 5925007271442 | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | ||||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Sm3-25a50vdc28 | 1 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAJE | THREAD PITCH DIAMETERS | 0 3503 TO 0 3537 INCHES |
AAQL | BODY STYLE | SINGLE POLE TYPE |
ABXD | BUSHING LENGTH | 0 360 INCHES MINIMUM AND 0 380 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 1 448 INCHES MINIMUM AND 1 510 INCHES MAXIMUM |
ADAT | BODY WIDTH | 0 567 INCHES MINIMUM AND 0 629 INCHES MAXIMUM |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 0 870 INCHES MINIMUM AND 0 880 INCHES MAXIMUM |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 1 524 INCHES MINIMUM AND 1 586 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 1 |
APNQ | ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED BUSHING WPANEL SEAL |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 250 0 AMPERES DC SINGLE LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 240 0 AC AND 32 0 DC SINGLE LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000 0 AC AND 1000 0 DC SINGLE LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SINGLE LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC SINGLE LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SINGLE LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 115 0 SINGLE LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE ONE |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SINGLE LOCATION |
CQJX | NOMINAL THREAD SIZE | 0 375 INCHES |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 0 140 NOMINAL AT 300 PCT AND 0 080 NOMINAL AT 400 PCT SINGLE LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | SHOCKPROOF AND VIBRATIONPROOF AND HERMETICALLY SEALED |
FREQ | FREQUENCY IN HERTZ | 60 0 SINGLE LOCATION |
THSD | THREAD SERIES DESIGNATOR | UNEF |
TTQY | TERMINAL TYPE AND QUANTITY | 2 WIRE HOOK |
At Complete Sourcing Solutions, You Can Get Quote for Your Required Part Number Within 15 Minutes. Just Fill Out the Instant RFQ Form.